CDS-20 Clock Distribution System

TECHNICAL SPECIFICATIONS

Reference Input Signal: Sinusoidal or square wave NRZ with a 1 Volt RMS minimum amplitude.
Reference Input Frequency: 1.0, 1.544, or 5.0 MHz, depending on reference module used.
Reference Input Impedance: 50, 100 or 600 , depending on reference module used.
Output Frequencies: See Table for standard and optional frequencies available.
Output Stability: Dependant on the external or internal references; the CDS-20 may be configured to operate with up to 3 separate external references, using a cesium beam, Loran, GPS, or WWW source, for a stability of one part in 10 to the 12th.
Output Interface: Conforms to the requirements of MIL-STD-188-114, balanced or unbalanced, EIA-RS-422, RS-423, and RS-232C. Balanced outputs recommended for frequencies above 1 MHz,
Mechanical:  
Power Rqmts:
115 or 230 VAC, ±10%, 48-62 Hz
    Operating Temp:
0º to ±40ºC (32º to +104ºF)
    Relative Humditiy:
Up to 95% (non-condensing)
    Altitude:
Up to 10,000 feet
    Dimensions:
7.0" high (17.8 cm) x 17.3" wide (43.8 cm) x 18.5" deep (47.0 cm)
    Weight:
Approx. 57 lbs. (25.7 kg) fully laden; chassis 34 lbs (15.4 kg) empty

___Email this Page:

VERSITRON INC.
83 Albe Drive - Suite C - Newark, DE 19702
Need Help? Call 1-800-537-2296, or 302-894-0699 Fax. 302-894-0624
www.versitron.com
fiberlink@versitron.com